An IBM IMS FDBR region S0C4 abend occurs in module DLAXRELx when the following conditions exist: -You are running a supported IBM IMS version. -You have version 6.9.00 of one of the listed products installed on the system. -You have an IBM IMS Fast Database Recovery (FDBR) region enabled. -You have an IBM IMS Directory (using IMS Managed ACBs) enabled. -You execute a DELTA IMS DB or APPLCTN ADD, DELETE, REVISE, or RELOAD request on the IMS associated with its FDBR region. The following messages show an example of the typical register contents when the abend occurs in the FDBR region that is monitoring its associated IMS: DFS629I IMS RST TCB ABEND - SYS 0C4 DFS629I PSW AT ERROR = 077C0000 800FA686 DFS629I MODID = DLAXREL7 ZDLA690 EPA = 39C9F1BC DFS629I R0-3 0000000C 000FB778 00000000 002DC8F8 DFS629I R4-7 00B9F100 000C0A00 2EE9B060 00000000 DFS629I R8-11 000C0D90 2EAB7CC0 2EAB7CC0 00B64860 DFS629I R12-15 000FA460 002DC508 800FA57A 000FC528 |
DELTA IMS has been modified to support IMS FDBR regions in a managed ACB environment. PTF BQQ4735 resolves this issue. Note: After applying PTF BQQ4735, you must restart both the IMS control region and its associated FDBR region (with any type of restart) to make the change effective. |